Customization: | Available |
---|---|
After-sales Service: | Online Service |
Type: | Water-Cooled |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product Introduction:
1. Optional explosion-proof design for enhanced safety and durability, catering to specialized needs.
2. Optional air blowing and water return function for efficient and seamless operation.
3. Integrated display for accurate monitoring of return water temperature, ensuring optimal performance.
4. Automatic air-exhausting feature after startup to maintain system efficiency and stability.
5. Convenient switch of heating power, allowing precise control over temperature settings.
6. Optional instant cooling shut-down function for rapid response and enhanced safety.
7. Optional RS485 communication feature, enabling automated management for streamlined operations.
8. BY-PASS pressure release loop, expertly designed for effective hot water management.
9. Tailor-made multi-point temperature control function for customized heating solutions.
10. Temperature control range: Inlet water temperature plus 25°C,extendingup to120°C.
11. Special qualification for pipe components, ensuring reliability and longevity.
12. Control mode options: Microcomputer or PLC, providing flexibility and precision.
13. Comprehensive safety protection, with fault display for easy repair and maintenance, ensuring peace of mind.
ITEM | UNIT | MODEL | |||||
ARD-30-24 | ARD-30-36 | ARD-40-48 | ARD-50-72 | ARDN-50-72 | ARDN-75-90 | ||
Temp control range | ºC | Inlet water temperature +25ºC~98ºC | |||||
Temp control accuracy | ºC | PID ±1ºC | |||||
Power supply | AC 3N-380V/400V-50HZ+PE | ||||||
Heat transfer medium | Water | ||||||
Cooling mode | Direct cooling | Direct heating | |||||
Heating capacity | KW | 24 | 36 | 48 | 72 | 72 | 90 |
Motor power | KW | 2.2 | 2.2 | 3.0 | 4.0 | 3.0 | 5.5 |
Pump flow | L/min | 233 | 233 | 255 | 267 | 267 | 334 |
Pump pressure | m | 20 | 20 | 25 | 30 | 34 | 47 |
Max. power consumption | KW | 26.2 | 38.2 | 51 | 76 | 75 | 95.5 |
Alarm function | Pump reversal/Water shortage/Overloading/High pressure | ||||||
Cooling water pipe | inch | 1/2 | 1/2 | 1/2 | 3/4 | 3/4 | 3/4 |
Circulating water pipe | inch | 1.2 | 1.2 | 1.5 | 1.5 | 2 | 2 |
Size(L×W×H) | mm | 900*420*950 | 1200*420*1100 | 1400*500*1250 | 1720*550*1350 |