Customization: | Available |
---|---|
After-sales Service: | Online Service |
Type: | Water-Cooled |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product Introduction:
1. Explosion-proof design (optional)
2. Air blowing and return oil function (optional)
3.Display for return oil temperature
4. Automatic air-exhausting function after startup
5. Switch of heating power
6.Instant cooling shut-down function(optional)
7. RS485 communication function for automated management (optional)
8.BY-PASS pressure release loop for hot oil
9. Range of temperature control: Inlet water temperature +45ºC→180ºC
10. Control mode: Microcomputer or PLC (optional)
(ITEM) | (UNIT) | MODEL | ||||
AOS-05A | AOS-10(A) | AOS-20 | AOS-30 | AOS-30-24 | ||
Temp control range | ºC | Inlet water temperature +45ºC-180ºC | ||||
Tempcontrol accuracy | ºC | PID±1ºC | ||||
Power supply | / | AC 3N-380/400V-50HZ(3phase+Earth) | ||||
Heat transfer medium | / | Thermal conductive oil | ||||
Cooling method | / | Indirect cooling | ||||
Heating capacity | KW | 6 | 9 | 12 | 12 | 24 |
Motor power | KW | 0.37 | 0.75 | 1.5 | 2.2 | 2.2 |
Pump flow | L/min | 22 | 85/33 | 120 | 150 | 150 |
Pump head | m | 13 | 15/20 | 17 | 20 | 20 |
Max.power consumption | KW | 6.37 | 9.75 | 10.5 | 14.2 | 26.2 |
Alarm function | / | /// Pump reversal/Oil shortage/Overload/Abnormal heating |
||||
Cooling water pipe | inch | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 |
Circulating oil pipe | inch | 3/8*2 | 3/8*4 / 3/8*2 | 3/8*4 | 1 | 1 |
Size(L×W×H) | mm | 630*325*745 | 630*325*745 | 630*325*745 | 900*420*850 | 1200*420*1000 |
Weight | kg | 75 | 80 | 88 | 150 | 200 |