Product Introduction:
1. Featuring state-of-the-art imported compressor heads sourced from leading European and American manufacturers, ensuring unparalleled performance and reliability.
2. The electrical equipment integrates world-class brands like SIEMENS, Weidmuller, LG, MOELLER and West, promising superior functionality and seamless operation.
3. Robust steel pipes are meticulously welded using the cutting-edge anaerobic welding method, enhancing durability and longevity.
4. Control Method: Choose between imported microcomputer or PLC control, offering flexibility and precision (optional).
5. Equipped with RS485 communication function, enabling comprehensive automated management and streamlined operations (optional).
6. Enjoy complete safety protection, intuitive fault display, and simplified repair and maintenance that do not require specialized personnel.
7. Cutting-edge evaporators and condensers engineered to achieve over 30% energy savings, optimizing efficiency and reducing operational costs.
8. Constructed with imported advanced components, designed to deliver exceptional longevity and reliable performance throughout its service life.
9. Models C-20 and above incorporate dual sets of compressor heads, offering versatile usage either independently or simultaneously for enhanced adaptability.
ITEM | UNIT |
ADDC-36 | ADDC-48 | ADDM-36 | ADDM-48 |
OT320D-24 | OT320D-30 | OT320D-24/2 | OT320D-30/2 | ||
Temp control range | ºC | Inlet water temperature +45ºC~320ºC | |||
Temp control accuracy | ºC | PID ±1 | |||
Power supply | AC 3N-380V/400V-50HZ(3 phase+Earth) | ||||
Heat transfer medium | Thermo conductive oil | ||||
Cooling method | Indirect Cooling | ||||
Cooling capacity | 0.36 | 0.48 | 0.36+0.36 | 0.48+0.48 | |
Expansion tank | L | 40 | 67 | 62 | 62 |
Heating capacity | KW | 15*2 | 20*2 | 30+30 | 40+40 |
Moter power | KW | 1.1 | 3 | 1.1+1.1 | 3.0+3.0 |
Pump flow | L/min | 30 | 75 | 30+30 | 75+75 |
Max. power consumption | KW | 31 | 43 | 62 | 86 |
Alarm function | //// Pump reversal/Oil shortage/Overheating/Overload/Abnormal heating |
||||
Cooling water pipe | inch | 1/2 | 1/2 | 3/4 | 3/4 |
Circulating oil pipe | inch | 3/4 | 1 | 3/4+3/4 | 1+1 |
Size(L×W×H) | mm | 1400*500*1150 | 1650*550*1250 | 1380*650*1400 | 1380*650*1400 |