Customization: | Available |
---|---|
After-sales Service: | Online Service |
Type: | Water-Cooled |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product Introduction:
1. Experience peace of mind with our optional Explosion-proof design, engineered for maximum safety in industrial applications.
2. Enhance your operations with our optional Air blowing and return water functions, designed to optimize performance and efficiency.
3. Keep track of your system's efficiency with a Display for return water temperature.
4. Enjoy seamless operation with our Automatic air-exhausting function after startup, ensuring a smooth start every time.
5. Control your energy usage with the versatile Switch of heating power, tailored to your needs.
6. Benefit from our Instant cooling shut-down feature, an optional function that helps maintain system integrity and longevity.
7. Harness the power of automation with our RS485 communication function for automated management, available as an option.
8. Ensure system protection with the BY-PASS pressure release loop for hot water, a safeguard for optimal pressure levels.
9. Precision at your fingertips with our Customized multi-point temperature control function, tailored to meet varied temperature demands.
10. Achieve perfect temperature regulation with a Range of temperature control: starting from Inlet water temperature+25ºC→120ºC, offering flexibility and precision.
11. Special Qualification for pipe component ensures reliability and robustness in industrial environments.
12. Select your preferred Control mode: Microcomputer or PLC, available as an optional feature for enhanced customization.
13. Prioritize safety with Complete safety protection, fault display, and user-friendly repair and maintenance, designed for ease of use.
ITEM | (UNIT) | MODEL | |||
AWM-05A | AWM-10(A) | AWM-20 | AWMD-10 | ||
Temp control range | ºC | Inlet water temperature +25ºC~100ºC | |||
Tempcontrol accuracy | ºC | PID±1ºC | |||
Power supply | / | AC 3N-380/400V-50HZ(3phase+Earth) | |||
Heat transfer medium | / | Water | |||
Cooling method | / | Direct cooling | |||
Heating capacity | KW | 6 | 9 | 12 | 9+9 |
Motor power | KW | 0.37 | 0.75 | 1.5 | 0.75+0.75 |
Pump flow | L/min | 26 | 133/33 | 167 | 133+133 |
Pump head | m | 15 | 16/20 | 18 | 16 |
Max.power consumption | KW | 6.37 | 9.75 | 13.5 | 19.5 |
Alarm function | / | // Pump reversal/Water shortage/Overload |
|||
Cooling water pipe | inch | 1/2 | 1/2 | 1/2 | 1/2 |
Circulating water pipe | inch | 3/8*2 | 3/8*4 / 3/8*2 | 3/8*4 | (3/8*4)*2 |
Size(L×W×H) | mm | 620*325*645 | 620*325*645 | 620*325*645 | 800*420*750 |
kg | 67 | 72 | 80 | 150 |