Customization: | Available |
---|---|
After-sales Service: | Online Service |
Type: | Water-Cooled |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product Introduction:
1. Featuring the finest imported compressor heads from Europe and America, ensuring unparalleled performance and reliability.
2. Harnessing top-tier electrical components from industry leaders like SIEMENS, Weidmuller, LG, MOELLER, and West, for unmatched efficiency and durability.
3. Utilizing anaerobic welding techniques for steel pipes, guaranteeing exceptional strength and longevity.
4. Offering advanced control options with your choice of imported microcomputer or PLC control systems, tailored to your specific needs.
5. Equipped with Rs485 communication capability, enabling seamless integration into automated management systems for enhanced operational efficiency (optional).
6. Comprehensive safety features, real-time fault display, and user-friendly maintenance eliminate the need for professional technicians.
7. High-efficiency evaporators and condensers deliver energy savings of over 30%, ensuring cost-effective and environmentally friendly operation.
8. Incorporating only the most advanced imported components, our machines promise a long service life and consistent performance.
9. Models C-20 and above are equipped with dual compressor heads that can operate independently or together, providing flexible and reliable temperature control solutions.
ITEM | UNIT |
ADDC-36 | ADDC-48 | ADDM-36 | ADDM-48 |
OT320D-24 | OT320D-30 | OT320D-24/2 | OT320D-30/2 | ||
Temp control range | ºC | Inlet water temperature +45ºC~320ºC | |||
Temp control accuracy | ºC | PID ±1 | |||
Power supply | AC 3N-380V/400V-50HZ(3 phase+Earth) | ||||
Heat transfer medium | Thermo conductive oil | ||||
Cooling method | Indirect Cooling | ||||
Cooling capacity | 0.36 | 0.48 | 0.36+0.36 | 0.48+0.48 | |
Expansion tank | L | 40 | 67 | 62 | 62 |
Heating capacity | KW | 15*2 | 20*2 | 30+30 | 40+40 |
Moter power | KW | 1.1 | 3 | 1.1+1.1 | 3.0+3.0 |
Pump flow | L/min | 30 | 75 | 30+30 | 75+75 |
Max. power consumption | KW | 31 | 43 | 62 | 86 |
Alarm function | //// Pump reversal/Oil shortage/Overheating/Overload/Abnormal heating |
||||
Cooling water pipe | inch | 1/2 | 1/2 | 3/4 | 3/4 |
Circulating oil pipe | inch | 3/4 | 1 | 3/4+3/4 | 1+1 |
Size(L×W×H) | mm | 1400*500*1150 | 1650*550*1250 | 1380*650*1400 | 1380*650*1400 |