Immerse yourself in the exceptional quality and superior performance of our Heating Series Products. Our cutting-edge solutions redefine the standards in precision and efficiency, setting new benchmarks for excellence. Experience the next level of industrial heating with our innovative technology designed to enhance your operations with unmatched reliability and superior performance.
(ITEM) | (UNIT) | Model | ||||||||
AEOT-10BF-18 | AEOT-20BF-24 | AEOT-30BF-36 | AEOT-40BF-45 | AEOT-50BF-60 | AEOT-75BF-75 | AEOT-75BF-80 | AEOT-100BF-90 | |||
Temp control range | ºC | +25ºC-400ºCInlet water temperature +25ºC-400ºC | ||||||||
Tempcontrol accuracy | ºC | PID±1ºC | ||||||||
Power supply | / | 3P AC380V/480V 50HZ(3phase+Earth) | ||||||||
Heat transfer medium | / | Thermo conductive oil | ||||||||
Cooling method | / | Indirect cooling | Without Cooling | |||||||
Expansion tank | L | 67 | 67 | 67 | 100 | 100 | 100 | 150 (External) |
150 (External) |
|
Heating capacity | KW | 15/18 | 18/24 | 30/36 | 40/45 | 50/60 | 75 | 80(40+40)/90(45+45) | 96(48+48) | |
Pump power | KW | 1.5 | 1.5 | 2.2 | 2.2 | 3.0 | 4.0 | 4.0 | 5.5 | |
Pump flow | m³/h | 6 | 6 | 10 | 12.5 | 16 | 12.5/18 | 12.5/18 | 30/34 | |
Pump head | m | 28 | 28 | 28 | 30 | 32 | 50/38 | 50/38 | 50/40 | |
Max.power consumption | KW | 19.5 | 25.5 | 38.5 | 48 | 63 | 79 | 94 | 102 | |
Alarm function | / | //// Pump reversal/Oil shortage/Overheating/Overload/Abnormal heating |
||||||||
Cooling water pipe | inch | 1/2″ | 1/2″ | 1/2″ | 1/2″ | 1/2″ | 1/2″ | NA | NA | |
Circulating oil pipe | inch | 1″ | 1″ | 1″ | 1-1/4″ | 1-1/4″ | 1-1/2″ | 1-1/2″ | 2″ | |
Size(L×W×H) | mm | 2100*600*1350 | 2100*600*1350 | 2250*700*1550 | 2250*800*1650 | 2450*800*1650 | 2450*800*1650 | 2300*800*1800 | 2300*800*1800 |