Customization: | Available |
---|---|
After-sales Service: | Online Service |
Type: | Water-Cooled |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product Introduction:
1. Explosion-proof design (optional): Experience safety like never before with our optional explosion-proof feature, ensuring unparalleled protection.
2. Air blowing and return water function (optional): Optimize your system's efficiency with our versatile air blowing and return water option, tailored for performance.
3. Display for return water temperature: Monitor with ease using our intuitive display, providing precise return water temperature readings at a glance.
4. Automatic air-exhausting function after startup: Seamlessly eliminate air build-up post-startup with our automatic air-exhausting feature, enhancing operational efficiency.
5. Switch of heating power: Customize your heating power with our user-friendly switch, offering adaptable solutions for varied requirements.
6. Instant cooling shut-down function (optional): Benefit from rapid response with our optional instant cooling shut-down feature, ensuring swift operational adjustments.
7. RS485 communication function for automated management (optional): Elevate your management capabilities through optional RS485 communication, enabling streamlined automation.
8. BY-PASS pressure release loop for hot water: Experience seamless operation with our BY-PASS pressure release loop, ensuring optimal hot water flow control.
9. Customized multi-point temperature control function: Achieve precise thermal regulation with our customizable multi-point temperature control, tailored to your specifications.
10. Range of temperature control: Inlet water temperature+25: Control your environment with precision, offering temperature ranges from inlet water temperature plus 25°CºC→120ºC
11. Special Qualification for pipe component: Trust in our specially qualified pipe components, designed for superior reliability and performance.
12. Control mode: Microcomputer or PLC (optional): Choose between microcomputer or optional PLC control modes, catering to diverse operational preferences.
13. Complete safety protection, fault display, easy repair and maintenance: Enjoy peace of mind with our thorough safety protections, fault display, and effortless maintenance ensuring longevity.
ITEM | UNIT | MODEL | |||||
ARD-30-24 | ARD-30-36 | ARD-40-48 | ARD-50-72 | ARDN-50-72 | ARDN-75-90 | ||
Temp control range | ºC | Inlet water temperature +25ºC~98ºC | |||||
Temp control accuracy | ºC | PID ±1ºC | |||||
Power supply | AC 3N-380V/400V-50HZ+PE | ||||||
Heat transfer medium | Water | ||||||
Cooling mode | Direct cooling | Direct heating | |||||
Heating capacity | KW | 24 | 36 | 48 | 72 | 72 | 90 |
Motor power | KW | 2.2 | 2.2 | 3.0 | 4.0 | 3.0 | 5.5 |
Pump flow | L/min | 233 | 233 | 255 | 267 | 267 | 334 |
Pump pressure | m | 20 | 20 | 25 | 30 | 34 | 47 |
Max. power consumption | KW | 26.2 | 38.2 | 51 | 76 | 75 | 95.5 |
Alarm function | Pump reversal/Water shortage/Overloading/High pressure | ||||||
Cooling water pipe | inch | 1/2 | 1/2 | 1/2 | 3/4 | 3/4 | 3/4 |
Circulating water pipe | inch | 1.2 | 1.2 | 1.5 | 1.5 | 2 | 2 |
Size(L×W×H) | mm | 900*420*950 | 1200*420*1100 | 1400*500*1250 | 1720*550*1350 |