Customization: | Available |
---|---|
After-sales Service: | Online Service |
Type: | Water-Cooled |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product Introduction:
1. Explosion-proof design (optional)
2.Air blowing and return oil function (optional)
3. Display for return oil temperature
4. Automatic air-exhausting function after startup
5.Switch of heating power
6. RS485 communication function for automated management (optional)
7.delay cooling down when shut down machine(optional).
8. Isolated electric cabinet deisgn
9. BY-PASS pressure release loop for hot oil
10.Customized multi-point temperature control function
11. Customized pump and heating power
12.Range of temperature control: Inlet water temperature +45ºC→300ºC
(ITEM) | (UNIT) | MODEL | |||||
AEOT-20 | AEOT-30 | AEOT-40 | AEOT-50 | AEOT-75 | AEOT-100 | ||
Temp control range | ºC | Inlet water temperature +45ºC-300ºC | |||||
Tempcontrol accuracy | ºC | PID±1ºC | |||||
Power supply | / | AC 3N-380/400V-50HZ(3phase+Earth) | |||||
Heat transfer medium | / | Thermal conductive oil | |||||
Cooling method | / | Indirect cooling | |||||
Expansion tank capacity | L | 24 | 67 | 67 | 67 | 67 | 98 |
Heating capacity | KW | 24 | 45 | 60 | 60 | 90 | 98 |
Motor power | KW | 1.5 | 2.2 | 2.2 | 3 | 4 | 5.5 |
Pump flow | L/min | 108 | 166 | 208 | 266 | 300 | 416 |
Pump head | m | 28 | 28 | 30 | 32 | 38 | 40 |
Max.power consumption | KW | 25.5 | 47.2 | 62.2 | 63 | 94 | 103.5 |
Alarm function | / | //// Pump reversal/Oil shortage/Overheating/Overload/Abnormal heating |
|||||
Cooling water pipe | inch | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 |
Circulating water pipe | inch | 1 | 1 | 1-1/4 | 1-1/4 | 1-1/2 | 2 |
Size(L×W×H) | mm | 1200*420*1000 | 1720*550*1250 | 1720*550*1250 | 1720*550*1250 | 1720*550*1250 | 1720*600*1400 |
Weight | kg | 220 | 405 | 465 | 500 | 580 | 625 |