Customization: | Available |
---|---|
After-sales Service: | Online Service |
Type: | Water-Cooled |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product Introduction:
1. Featuring top-tier compressor heads imported directly from Europe and America, ensuring industry-leading performance.
2. Equipped with electrical components from renowned brands such as SIEMENS, Weidmuller, LG, MOELLER, and West, guaranteeing exceptional reliability.
3. Steel pipes are expertly welded using the anaerobic welding method for superior durability and integrity.
4. Control Method: Choose between advanced imported microcomputer controls or sophisticated PLC control systems (optional).
5. Integrated RS485 communication function allows for seamless automated management (optional).
6. Comprehensive safety protection systems coupled with fault displays enable easy repair and maintenance without the need for professional personnel.
7. High-efficiency evaporators and condensers can achieve energy savings of over 30%, making it both eco-friendly and cost-effective.
8. Utilizing premium imported components ensures an extended service life, delivering dependable operations year after year.
9. Models C-20 and above come with dual compressor heads that can operate independently or simultaneously for enhanced flexibility and efficiency.
ITEM | UNIT |
ADDC-36 | ADDC-48 | ADDM-36 | ADDM-48 |
OT320D-24 | OT320D-30 | OT320D-24/2 | OT320D-30/2 | ||
Temp control range | ºC | Inlet water temperature +45ºC~320ºC | |||
Temp control accuracy | ºC | PID ±1 | |||
Power supply | AC 3N-380V/400V-50HZ(3 phase+Earth) | ||||
Heat transfer medium | Thermo conductive oil | ||||
Cooling method | Indirect Cooling | ||||
Cooling capacity | 0.36 | 0.48 | 0.36+0.36 | 0.48+0.48 | |
Expansion tank | L | 40 | 67 | 62 | 62 |
Heating capacity | KW | 15*2 | 20*2 | 30+30 | 40+40 |
Moter power | KW | 1.1 | 3 | 1.1+1.1 | 3.0+3.0 |
Pump flow | L/min | 30 | 75 | 30+30 | 75+75 |
Max. power consumption | KW | 31 | 43 | 62 | 86 |
Alarm function | //// Pump reversal/Oil shortage/Overheating/Overload/Abnormal heating |
||||
Cooling water pipe | inch | 1/2 | 1/2 | 3/4 | 3/4 |
Circulating oil pipe | inch | 3/4 | 1 | 3/4+3/4 | 1+1 |
Size(L×W×H) | mm | 1400*500*1150 | 1650*550*1250 | 1380*650*1400 | 1380*650*1400 |