Product Introduction:
1. Opt for our explosion-proof design for heightened safety in challenging environments. (optional)
2. Experience enhanced efficiency with our air blowing and return oil function. (optional)
3. Stay informed with our intuitive display that shows return oil temperature, ensuring precise monitoring.
4. Enjoy the convenience of our automatic air-exhausting function, activated right after startup, for seamless operation.
5. Benefit from the adaptable switch of heating power, tailored to your unique requirements.
6. Utilize the RS485 communication function to integrate automated management seamlessly. (optional)
7. Protect your equipment with a delayed cooling down feature upon shutdown, safeguarding its longevity. (optional)
8. Our isolated electric cabinet design ensures increased protection and reliability.
9. The BY-PASS pressure release loop facilitates safe and efficient hot oil handling.
10. Benefit from a customized multi-point temperature control function, tailored to fit your process needs.
11. Customize your experience with options for both pump and heating power, perfectly aligning with your specifications.
12. Achieve precise temperature control within the range of: Inlet water temperature +45ºC→300ºC, ensuring optimal performance across a broad spectrum.
(ITEM) | (UNIT) | MODEL | |||||
AEOT-20 | AEOT-30 | AEOT-40 | AEOT-50 | AEOT-75 | AEOT-100 | ||
Temp control range | ºC | Inlet water temperature +45ºC-300ºC | |||||
Tempcontrol accuracy | ºC | PID±1ºC | |||||
Power supply | / | AC 3N-380/400V-50HZ(3phase+Earth) | |||||
Heat transfer medium | / | Thermal conductive oil | |||||
Cooling method | / | Indirect cooling | |||||
Expansion tank capacity | L | 24 | 67 | 67 | 67 | 67 | 98 |
Heating capacity | KW | 24 | 45 | 60 | 60 | 90 | 98 |
Motor power | KW | 1.5 | 2.2 | 2.2 | 3 | 4 | 5.5 |
Pump flow | L/min | 108 | 166 | 208 | 266 | 300 | 416 |
Pump head | m | 28 | 28 | 30 | 32 | 38 | 40 |
Max.power consumption | KW | 25.5 | 47.2 | 62.2 | 63 | 94 | 103.5 |
Alarm function | / | //// Pump reversal/Oil shortage/Overheating/Overload/Abnormal heating |
|||||
Cooling water pipe | inch | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 |
Circulating water pipe | inch | 1 | 1 | 1-1/4 | 1-1/4 | 1-1/2 | 2 |
Size(L×W×H) | mm | 1200*420*1000 | 1720*550*1250 | 1720*550*1250 | 1720*550*1250 | 1720*550*1250 | 1720*600*1400 |
Weight | kg | 220 | 405 | 465 | 500 | 580 | 625 |