Customization: | Available |
---|---|
After-sales Service: | Online Service |
Type: | Water-Cooled |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product Introduction:
1. Explosion-proof design (optional)
2. Air blowing and return oil function (optional)
3. Equipped with a display for monitoring return oil temperature
4. Features an automatic air-exhausting function post-startup
5. Switch to adjust heating power
6. RS485 communication function for seamless automated management (optional)
7. Optional feature to delay cooling down upon machine shutdown
8. Ingenious isolated electric cabinet design
9. BY-PASS pressure release loop crafted for hot oil safety
10. Customized multi-point temperature control capabilities
11. Tailored options for pump and heating power to suit your needs
13. Temperature control range: Starting from Inlet water temperature +45ºC, stretching up to300ºC
13. Special qualification for pipe components, ensuring stellar performance
14. Control mode options: Microcomputer or PLC, tailored to your preference (optional)
15. Comprehensive safety protection, fault display, designed for easy repair and maintenance
ITEM | UNIT | Model | ||||||
YGW/YDL-120(D) | YGW/YDL-150(D) | YGW/YDL-200(D) | YGW/YDL-240(D) | YGW/YDL-300(D) | YGW/YDL-360(D) | YGW/YDL-400(D) | ||
Rated outlet temperature | ºC | 280ºC | ||||||
Temp control accuracy | ºC | PID +/- 1ºC | ||||||
Rated Power | KW | 120 | 150 | 200 | 240 | 300 | 360 | 400 |
Thermal Efficiency | % | 98 | ||||||
Design pressure | Mpa | 0.75 | ||||||
Pump power | KW | 7.5 | 11 | 15 | 15 | 22 | 22 | 22 |
Pump flow | m³/h | 25 | 40 | 50 | 50 | 100 | 100 | 100 |
Pump pressure | m | 54 | 40 | 50 | 50 | 55 | 55 | 55 |
Connecting pipe size | inch | 2.0 | 2.5 | 2.5 | 3.0 | 3.0 | 3.0 | 3.0 |
Max power consumption | KW | 127.5 | 161.0 | 215.0 | 255.0 | 322.0 | 382.0 | 422.0 |
Size(L x W x H)×W×H) | mm | 1900*750*1500 | 2000*850*1950 | 2000*1000*2000 | 2000*1000*2000 | 2200*1600*2000 | 2400*1600*2000 | 2400*1800*2250 |