Customization: | Available |
---|---|
After-sales Service: | Online Service |
Type: | Oil-Heating |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Products for Heating Series - Immerse yourself in our exquisite collection of heating solutions designed to deliver optimal performance and consistent results. Our heating series represents the embodiment of innovation, crafted to meet the highest standards of quality and functionality.
(ITEM) | (UNIT) | Model | ||||||||
AEOT-10BF-18 | AEOT-20BF-24 | AEOT-30BF-36 | AEOT-40BF-45 | AEOT-50BF-60 | AEOT-75BF-75 | AEOT-75BF-80 | AEOT-100BF-90 | |||
Temp control range | ºC | +25ºC-400ºCInlet water temperature +25ºC-400ºC | ||||||||
Tempcontrol accuracy | ºC | PID±1ºC | ||||||||
Power supply | / | 3P AC380V/480V 50HZ(3phase+Earth) | ||||||||
Heat transfer medium | / | Thermo conductive oil | ||||||||
Cooling method | / | Indirect cooling | Without Cooling | |||||||
Expansion tank | L | 67 | 67 | 67 | 100 | 100 | 100 | 150 (External) |
150 (External) |
|
Heating capacity | KW | 15/18 | 18/24 | 30/36 | 40/45 | 50/60 | 75 | 80(40+40)/90(45+45) | 96(48+48) | |
Pump power | KW | 1.5 | 1.5 | 2.2 | 2.2 | 3.0 | 4.0 | 4.0 | 5.5 | |
Pump flow | m³/h | 6 | 6 | 10 | 12.5 | 16 | 12.5/18 | 12.5/18 | 30/34 | |
Pump head | m | 28 | 28 | 28 | 30 | 32 | 50/38 | 50/38 | 50/40 | |
Max.power consumption | KW | 19.5 | 25.5 | 38.5 | 48 | 63 | 79 | 94 | 102 | |
Alarm function | / | //// Pump reversal/Oil shortage/Overheating/Overload/Abnormal heating |
||||||||
Cooling water pipe | inch | 1/2″ | 1/2″ | 1/2″ | 1/2″ | 1/2″ | 1/2″ | NA | NA | |
Circulating oil pipe | inch | 1″ | 1″ | 1″ | 1-1/4″ | 1-1/4″ | 1-1/2″ | 1-1/2″ | 2″ | |
Size(L×W×H) | mm | 2100*600*1350 | 2100*600*1350 | 2250*700*1550 | 2250*800*1650 | 2450*800*1650 | 2450*800*1650 | 2300*800*1800 | 2300*800*1800 |