Customization: | Available |
---|---|
After-sales Service: | Online Service |
Type: | Water-Cooled |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product Introduction:
1. Explosion-proof design (optional) - Enhance safety with our optional explosion-proof design, ensuring maximum protection in volatile environments.
2. Air blowing and return water function (optional) - Optimize operational efficiency with the optional air blowing and water return functions for superior performance.
3. Display for return water temperature - Monitor system performance effortlessly with a clear and precise display of return water temperature.
4. Automatic air-exhausting function after startup - Enjoy seamless operation with automatic air-exhausting that engages immediately after startup.
5. Switch of heating power - Customize your thermal settings with an intuitive switch control for heating power adjustments.
6.Instant cooling shut-down function (optional) - Secure your equipment with instant cooling shut-down, available as an optional feature, to prevent overheating.
7.RS485 communication function for automated management (optional) - Integrate effortlessly into automated systems with the RS485 communication function for modern management solutions.
8. BY-PASS pressure release loop for hot water - Maintain system integrity with a BY-PASS pressure release loop, ensuring optimal hot water circulation.
9.Customized multi-point temperature control function - Achieve precise thermal management with a customizable multi-point temperature control function.
10. Range of temperature control: Inlet water temperature+25 - Offering a broad temperature control range, adjust from inlet water temperature plus 25ºC.ºC→120ºC
11.Special Qualification for pipe component - Confidence in quality with specially qualified pipe components tailored for durability and efficiency.
12. Control mode: Microcomputer or PLC (optional) - Choose between microcomputer or optional PLC control modes to suit your operational preferences.
13. Complete safety protection, fault display, easy repair and maintenance - Comprehensive safety features, clear fault displays, and straightforward maintenance ensure peace of mind and longevity.
ITEM | (UNIT) | MODEL | |||
AWM-05A | AWM-10(A) | AWM-20 | AWMD-10 | ||
Temp control range | ºC | Inlet water temperature +25ºC~100ºC | |||
Tempcontrol accuracy | ºC | PID±1ºC | |||
Power supply | / | AC 3N-380/400V-50HZ(3phase+Earth) | |||
Heat transfer medium | / | Water | |||
Cooling method | / | Direct cooling | |||
Heating capacity | KW | 6 | 9 | 12 | 9+9 |
Motor power | KW | 0.37 | 0.75 | 1.5 | 0.75+0.75 |
Pump flow | L/min | 26 | 133/33 | 167 | 133+133 |
Pump head | m | 15 | 16/20 | 18 | 16 |
Max.power consumption | KW | 6.37 | 9.75 | 13.5 | 19.5 |
Alarm function | / | // Pump reversal/Water shortage/Overload |
|||
Cooling water pipe | inch | 1/2 | 1/2 | 1/2 | 1/2 |
Circulating water pipe | inch | 3/8*2 | 3/8*4 / 3/8*2 | 3/8*4 | (3/8*4)*2 |
Size(L×W×H) | mm | 620*325*645 | 620*325*645 | 620*325*645 | 800*420*750 |
kg | 67 | 72 | 80 | 150 |