1. Featuring top-tier imported compressor heads sourced directly from Europe and America, our product guarantees unmatched reliability and performance.
2. We utilize premium electrical components from industry giants like SIEMENS, Weidmuller, LG, MOELLER, and West to ensure superior quality and durability.
3. Our steel pipes are meticulously welded using state-of-the-art anaerobic welding techniques for enhanced strength and longevity.
4. Equipped with versatile control options: choose between imported microcomputer systems or advanced PLC control for precise regulation.
5. Optional Rs485 communication capability allows seamless integration into automated management systems, enhancing operational efficiency.
6. Comprehensive safety features ensure peace of mind, while intuitive fault displays and easy repair procedures eliminate the need for specialized personnel.
7. Our high-efficiency evaporators and condensers are designed to deliver energy savings exceeding 30%, reducing operational costs significantly.
8. Utilization of cutting-edge imported components ensures a prolonged service life, offering long-term reliability and value.
9. Models C-20 and above come equipped with dual compressor systems, offering flexible operation options that can be tailored to your needs, either working separately or in tandem.
ITEM | UNIT |
ADDC-36 | ADDC-48 | ADDM-36 | ADDM-48 |
OT320D-24 | OT320D-30 | OT320D-24/2 | OT320D-30/2 | ||
Temp control range | ºC | Inlet water temperature +45ºC~320ºC | |||
Temp control accuracy | ºC | PID ±1 | |||
Power supply | AC 3N-380V/400V-50HZ(3 phase+Earth) | ||||
Heat transfer medium | Thermo conductive oil | ||||
Cooling method | Indirect Cooling | ||||
Cooling capacity | 0.36 | 0.48 | 0.36+0.36 | 0.48+0.48 | |
Expansion tank | L | 40 | 67 | 62 | 62 |
Heating capacity | KW | 15*2 | 20*2 | 30+30 | 40+40 |
Moter power | KW | 1.1 | 3 | 1.1+1.1 | 3.0+3.0 |
Pump flow | L/min | 30 | 75 | 30+30 | 75+75 |
Max. power consumption | KW | 31 | 43 | 62 | 86 |
Alarm function | //// Pump reversal/Oil shortage/Overheating/Overload/Abnormal heating |
||||
Cooling water pipe | inch | 1/2 | 1/2 | 3/4 | 3/4 |
Circulating oil pipe | inch | 3/4 | 1 | 3/4+3/4 | 1+1 |
Size(L×W×H) | mm | 1400*500*1150 | 1650*550*1250 | 1380*650*1400 | 1380*650*1400 |