(ITEM) | (UNIT) | Model | ||||||||
AEOT-10BF-18 | AEOT-20BF-24 | AEOT-30BF-36 | AEOT-40BF-45 | AEOT-50BF-60 | AEOT-75BF-75 | AEOT-75BF-80 | AEOT-100BF-90 | |||
Temp control range | ºC | +25ºC-400ºCInlet water temperature +25ºC-400ºC | ||||||||
Tempcontrol accuracy | ºC | PID±1ºC | ||||||||
Power supply | / | 3P AC380V/480V 50HZ(3phase+Earth) | ||||||||
Heat transfer medium | / | Thermo conductive oil | ||||||||
Cooling method | / | Indirect cooling | Without Cooling | |||||||
Expansion tank | L | 67 | 67 | 67 | 100 | 100 | 100 | 150 (External) |
150 (External) |
|
Heating capacity | KW | 15/18 | 18/24 | 30/36 | 40/45 | 50/60 | 75 | 80(40+40)/90(45+45) | 96(48+48) | |
Pump power | KW | 1.5 | 1.5 | 2.2 | 2.2 | 3.0 | 4.0 | 4.0 | 5.5 | |
Pump flow | m³/h | 6 | 6 | 10 | 12.5 | 16 | 12.5/18 | 12.5/18 | 30/34 | |
Pump head | m | 28 | 28 | 28 | 30 | 32 | 50/38 | 50/38 | 50/40 | |
Max.power consumption | KW | 19.5 | 25.5 | 38.5 | 48 | 63 | 79 | 94 | 102 | |
Alarm function | / | //// Pump reversal/Oil shortage/Overheating/Overload/Abnormal heating |
||||||||
Cooling water pipe | inch | 1/2″ | 1/2″ | 1/2″ | 1/2″ | 1/2″ | 1/2″ | NA | NA | |
Circulating oil pipe | inch | 1″ | 1″ | 1″ | 1-1/4″ | 1-1/4″ | 1-1/2″ | 1-1/2″ | 2″ | |
Size(L×W×H) | mm | 2100*600*1350 | 2100*600*1350 | 2250*700*1550 | 2250*800*1650 | 2450*800*1650 | 2450*800*1650 | 2300*800*1800 | 2300*800*1800 |