Customization: | Available |
---|---|
After-sales Service: | Online Service |
Type: | Water-Cooled |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product Introduction:
1. Fully closed tube design, using an efficient heat exchanger, to achieve rapid temperature rise and fall.
2. Unique expansion tank design ensures that the liquid in the expansion tank is always maintained at normal temperature.
3. High precision, intelligent temperature control.
4. High-efficiency heat exchangers and pipe heaters are used to increase heating and cooling rates.
5. Single cycle heat conduction medium, covering an extensive temperature range, eliminating the need to replace the liquid medium.
6. Fully sealed system to extend the life of thermal fluid.
7. Multifunctional alarm system and advanced security features.
8. Ultra-high temperature cooling technology enables direct cooling from an intense 200 degrees.
9. Utilizes analog adjustment to finely tune heating power, ensuring accurate temperature control and seamless power regulation.
(Item) | (Unit) | ACH05WS-9KW | ACH10WS-12KW | ACH15WS-18KW | ACH20WS-18KW | ACH25WS-24KW | ACH30WS-24KW | ACH35WS-36KW | |
Cooling Capacity | 200ºC | kW | 11 | 22 | 34 | 45 | 59 | 67 | 80 |
20ºC | kW | 11 | 22 | 34 | 45 | 59 | 67 | 80 | |
-5ºC | kW | 9 | 18 | 27.0 | 37 | 48 | 55 | 65 | |
-10ºC | kW | 7.2 | 14 | 22 | 29 | 38 | 44 | 52 | |
-20ºC | kW | 4.3 | 8.5 | 13 | 18 | 23 | 27 | 31 | |
Heating Capacity | kW | 9 | 12 | 18 | 18 | 24 | 24 | 36 | |
Circulating medium | |||||||||
Temperature control | Range | ºC | -25~+200 | ||||||
Accuracy | ºC | ±1 | |||||||
Compressor | Type | Piston | |||||||
Pump | Type | Centrifugal pump | |||||||
Evaporator | Type | /Stainless Steel Brazed/Shell And Tube Type | |||||||
Condenser | Type | Stainless Steel Brazed | |||||||
Flow | m³/h | 2 | 4 | 6 | 8 | 10 | 12 | 14 | |
Supply Flow | L/min | 30 | 90 | 110 | 160 | 200 | 250 | 265 | |
Supply Head | bar | 2 | 2 | 2 | 2 | 2 | 2 | 2 | |
Controller | Color LCD Touch Screen | ||||||||
Safety Protection Device | ,,,, Overload,Inverse Phase,High/Low Pressure,Oil Level,Antifreeze Protection,etc | ||||||||
Communication | Rs485 | ||||||||
Medium inlet/outlet pipe Size | Inch | 1" | 1.5" | 1.5" | 2" | 2" | 2" | 2.5" | |
Cooling water inlet/outlet pipe Size | Inch | 1" | 1.5 | 1.5" | 2" | 2" | 2.5" | 2.5" | |
Refrigerant | R404A | ||||||||
Power Input | kW | 13 | 20 | 30 | 34 | 44 | 48 | 64 | |
Net weight | kg | 500 | 550 | 620 | 720 | 850 | 960 | 1200 | |
Outline Size(L*W*H) | mm | 1400*800*2020 | 1400*800*2020 | 1400*1000*2020 | 1600*1000*2020 | 1600*1000*2020 | 2300*1200*2020 | 2300*1200*2020 |