Customization: | Available |
---|---|
After-sales Service: | Online Service |
Type: | Water-Cooled |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product Introduction:
1. Explosion-proof design (optional)
2. Air blowing and return oil function (optional)
3. Display for return oil temperature
4. Automatic air-exhausting function after startup
5. Switch of heating power
6. RS485 communication function for automated management (optional)
7. Delay cooling down when shutting down the machine (optional).
8. Isolated electric cabinet design
9. BY-PASS pressure release loop for hot oil
10. Customized multi-point temperature control function
11. Customized pump and heating power
12. Range of temperature control: Inlet water temperature +45ºC→300ºC
(ITEM) | (UNIT) | MODEL | |||||
AEOT-20 | AEOT-30 | AEOT-40 | AEOT-50 | AEOT-75 | AEOT-100 | ||
Temp control range | ºC | Inlet water temperature +45ºC-300ºC | |||||
Tempcontrol accuracy | ºC | PID±1ºC | |||||
Power supply | / | AC 3N-380/400V-50HZ(3phase+Earth) | |||||
Heat transfer medium | / | Thermal conductive oil | |||||
Cooling method | / | Indirect cooling | |||||
Expansion tank capacity | L | 24 | 67 | 67 | 67 | 67 | 98 |
Heating capacity | KW | 24 | 45 | 60 | 60 | 90 | 98 |
Motor power | KW | 1.5 | 2.2 | 2.2 | 3 | 4 | 5.5 |
Pump flow | L/min | 108 | 166 | 208 | 266 | 300 | 416 |
Pump head | m | 28 | 28 | 30 | 32 | 38 | 40 |
Max.power consumption | KW | 25.5 | 47.2 | 62.2 | 63 | 94 | 103.5 |
Alarm function | / | //// Pump reversal/Oil shortage/Overheating/Overload/Abnormal heating |
|||||
Cooling water pipe | inch | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 |
Circulating water pipe | inch | 1 | 1 | 1-1/4 | 1-1/4 | 1-1/2 | 2 |
Size(L×W×H) | mm | 1200*420*1000 | 1720*550*1250 | 1720*550*1250 | 1720*550*1250 | 1720*550*1250 | 1720*600*1400 |
Weight | kg | 220 | 405 | 465 | 500 | 580 | 625 |