Product Introduction:
1. Circulating pump
Featuring a magnetic drive, this innovative pump allows for prolonged continuous operation of the shaft, effectively preventing leaks and ensuring seamless performance.
2. High heat conduction efficiency
Experience unparalleled thermal efficiency with heat conduction capabilities approximately six times more effective than traditional heat conduction oils.
3. Heater
Engineered with a unique design that resists dry burning and scaling, this heater guarantees robust and reliable performance under demanding conditions.
4. IIOT
Integrated IIOT technology enables real-time monitoring of flow rate, pressure, and temperature, providing precise control and valuable insights for optimized operations.
5. Safe and reliable
Manufactured to stringent boiler standards, our product ensures unmatched safety and reliability for your peace of mind.
6. Energy conservation and environmental protection
Utilizing water as a heat conduction medium, this unit offers a cost-effective solution while promoting energy conservation and environmental protection.
ITEM | UNIT |
MODEL | |||
WT160D-18T/2 | WT160D-24T/2 | WT180D-24T/2 | WT200D-24T/2 | ||
Temp control range | ºC | +25ºC~160ºC Inlet water temperature |
+25ºC~180ºC Inlet water temperature |
+25ºC~200ºC Inlet water temperature |
|
Temp control accuracy | ºC | PID ±1 | |||
Power supply | AC 3N-380V/400V-50HZ(3 phase+Earth) | ||||
Heat transfer medium | Water | ||||
Cooling method | Indirect Cooling | ||||
Cooling power | KW | 200KW @160ºC | 200KW @160ºC | 350KW @180ºC | 400KW @200ºC |
Heating capacity | KW | 18*2 | 24*2 | 24*2 | 24*2 |
Motor power | KW | 1.7*2 | 2.5*2 | 2.5*2 | 2.5*2 |
Pump flow | L/min | 90 | 90 | 90 | 90 |
Pump head | m | 65 | 90 | 90 | 90 |
Max. power consumption | KW | 42 | 56 | 54.5 | 57.4 |
Alarm function | ////// Pump reversal/Water shortage/Overheating/Overloading/High pressure/pressure divergence/flow divergence |
||||
Circulating water pipe | inch | 3/4" *2 | 1" * 2 | ||
Cooling water pipe | inch | 3/4"+3/4" | 1"+1" | ||
Size(L×W×H) | mm | 1350*600*1300 |