Customization: | Available |
---|---|
After-sales Service: | Online Service |
Type: | Water-Cooled |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product Introduction:
1. Explosion-proof design (optional): Elevate your safety standards by choosing our optional explosion-proof design, crafted meticulously to enhance protection and ensure ultimate reliability during operations.
2. Air blowing and return water function (optional): Experience enhanced efficiency with our optional air blowing and return water function, designed to streamline your processes and optimize performance.
3. Display for return water temperature: Stay informed with our clear and precise display, providing accurate readings of return water temperature to facilitate seamless monitoring.
4. Automatic air-exhausting function after startup: Our innovative automatic air-exhausting function activates post-startup, ensuring optimal system performance and efficiency right from the beginning.
5. Switch of heating power: Flexibility at your fingertips with the switch of heating power, allowing you to adjust settings to meet your specific operational requirements with ease.
6. Instant cooling shut-down function (optional): Safeguard your equipment with the optional instant cooling shut-down function, providing immediate response in critical situations to protect and prolong your machinery's life.
7. RS485 communication function for automated management (optional): Embrace the future of automated management with our optional RS485 communication function, enabling streamlined and efficient control across operations.
8. BY-PASS pressure release loop for hot water: Ensure consistent performance with our BY-PASS pressure release loop, specifically designed to manage hot water pressure effortlessly and reliably.
9. Customized multi-point temperature control function: Tailor the temperature control to your exact needs with our customizable multi-point function, providing versatility and precision for diverse applications.
10. Range of temperature control: Inlet water temperature+25ºC→: Broaden your operational capabilities with our advanced temperature control range, allowing inlet water temperature to be heightened by 25ºC.120ºC: Achieve peak performance with the ability to control temperatures up to 120ºC, accommodating a wide range of industrial requirements.
11. Special Qualification for pipe component: Our pipe components boast a special qualification, ensuring superior quality and performance even in the most demanding environments.
12. Control mode: Microcomputer or PLC (optional): Choose between a microcomputer or the optional PLC control mode to match your specific needs, offering flexibility and precision in operational management.
13. Complete safety protection, fault display, easy repair and maintenance: Rest assured with comprehensive safety protection, intuitive fault displays, and straightforward repair and maintenance processes that keep your operations running smoothly and efficiently.
ITEM | UNIT | MODEL | |||||
ARD-30-24 | ARD-30-36 | ARD-40-48 | ARD-50-72 | ARDN-50-72 | ARDN-75-90 | ||
Temp control range | ºC | Inlet water temperature +25ºC~98ºC | |||||
Temp control accuracy | ºC | PID ±1ºC | |||||
Power supply | AC 3N-380V/400V-50HZ+PE | ||||||
Heat transfer medium | Water | ||||||
Cooling mode | Direct cooling | Direct heating | |||||
Heating capacity | KW | 24 | 36 | 48 | 72 | 72 | 90 |
Motor power | KW | 2.2 | 2.2 | 3.0 | 4.0 | 3.0 | 5.5 |
Pump flow | L/min | 233 | 233 | 255 | 267 | 267 | 334 |
Pump pressure | m | 20 | 20 | 25 | 30 | 34 | 47 |
Max. power consumption | KW | 26.2 | 38.2 | 51 | 76 | 75 | 95.5 |
Alarm function | Pump reversal/Water shortage/Overloading/High pressure | ||||||
Cooling water pipe | inch | 1/2 | 1/2 | 1/2 | 3/4 | 3/4 | 3/4 |
Circulating water pipe | inch | 1.2 | 1.2 | 1.5 | 1.5 | 2 | 2 |
Size(L×W×H) | mm | 900*420*950 | 1200*420*1100 | 1400*500*1250 | 1720*550*1350 |