Customization: | Available |
---|---|
After-sales Service: | Online Service |
Type: | Water-Cooled |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product Introduction:
1. Circulating pump
Featuring a magnetic drive, this pump ensures long-term operation with a continuous shaft that effectively prevents leaks, safeguarding your system with unmatched reliability.
2. High heat conduction efficiency
Experience heat conduction efficiency approximately six times greater than traditional heat conduction oil, optimizing performance and reducing energy costs.
3. Heater
Our heater boasts a unique design that resists dry burning and scale build-up, maintaining efficiency and extending the lifespan of the equipment.
4. IIOT
Seamlessly monitor flow rate, pressure, and temperature with cutting-edge IIOT technology, ensuring precision and control in every application.
5. Safe and reliable
Manufactured to rigorous boiler standards, our product guarantees safety and reliability, providing peace of mind in every operation.
6. Energy conservation and environmental protection
Utilizing water as the heat conduction medium, our product is not only cost-effective but also environmentally friendly, promoting sustainable practices.
ITEM | UNIT |
MODEL | |||
WT160D-18T/2 | WT160D-24T/2 | WT180D-24T/2 | WT200D-24T/2 | ||
Temp control range | ºC | +25ºC~160ºC Inlet water temperature |
+25ºC~180ºC Inlet water temperature |
+25ºC~200ºC Inlet water temperature |
|
Temp control accuracy | ºC | PID ±1 | |||
Power supply | AC 3N-380V/400V-50HZ(3 phase+Earth) | ||||
Heat transfer medium | Water | ||||
Cooling method | Indirect Cooling | ||||
Cooling power | KW | 200KW @160ºC | 200KW @160ºC | 350KW @180ºC | 400KW @200ºC |
Heating capacity | KW | 18*2 | 24*2 | 24*2 | 24*2 |
Motor power | KW | 1.7*2 | 2.5*2 | 2.5*2 | 2.5*2 |
Pump flow | L/min | 90 | 90 | 90 | 90 |
Pump head | m | 65 | 90 | 90 | 90 |
Max. power consumption | KW | 42 | 56 | 54.5 | 57.4 |
Alarm function | ////// Pump reversal/Water shortage/Overheating/Overloading/High pressure/pressure divergence/flow divergence |
||||
Circulating water pipe | inch | 3/4" *2 | 1" * 2 | ||
Cooling water pipe | inch | 3/4"+3/4" | 1"+1" | ||
Size(L×W×H) | mm | 1350*600*1300 |