Customization: | Available |
---|---|
After-sales Service: | Online Service |
Type: | Water-Cooled |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product Introduction:
1. Our product proudly incorporates imported compressor heads from the finest manufacturers in Europe and America, ensuring peak performance and reliability.
2. We use electrical components from top-tier brands like SIEMENS, Weidmuller, LG, MOELLER, and West, guaranteeing unmatched quality and efficiency.
3. The steel pipes feature robust construction through the superior anaerobic welding method, optimizing durability and strength.
4. Tailor your experience with our versatile control options: choose between imported microcomputer or PLC control, both designed to suit your specific needs.
5. With the optional RS485 communication function, our system seamlessly integrates into automated management setups, ensuring cutting-edge compatibility.
6. A comprehensive safety protection system is in place, complete with fault displays. Maintenance and repairs are user-friendly, eliminating the need for specialized technicians.
7. Our state-of-the-art evaporators and condensers are engineered for maximum efficiency, offering energy savings of over 30%.
8. We utilize high-grade, imported components renowned for their advanced technology and extended service life, setting a new standard in longevity.
9. Models C-20 and above feature dual compressor heads, offering the flexibility to operate them individually or in tandem for enhanced performance.
ITEM | UNIT |
ADDC-36 | ADDC-48 | ADDM-36 | ADDM-48 |
OT320D-24 | OT320D-30 | OT320D-24/2 | OT320D-30/2 | ||
Temp control range | ºC | Inlet water temperature +45ºC~320ºC | |||
Temp control accuracy | ºC | PID ±1 | |||
Power supply | AC 3N-380V/400V-50HZ(3 phase+Earth) | ||||
Heat transfer medium | Thermo conductive oil | ||||
Cooling method | Indirect Cooling | ||||
Cooling capacity | 0.36 | 0.48 | 0.36+0.36 | 0.48+0.48 | |
Expansion tank | L | 40 | 67 | 62 | 62 |
Heating capacity | KW | 15*2 | 20*2 | 30+30 | 40+40 |
Moter power | KW | 1.1 | 3 | 1.1+1.1 | 3.0+3.0 |
Pump flow | L/min | 30 | 75 | 30+30 | 75+75 |
Max. power consumption | KW | 31 | 43 | 62 | 86 |
Alarm function | //// Pump reversal/Oil shortage/Overheating/Overload/Abnormal heating |
||||
Cooling water pipe | inch | 1/2 | 1/2 | 3/4 | 3/4 |
Circulating oil pipe | inch | 3/4 | 1 | 3/4+3/4 | 1+1 |
Size(L×W×H) | mm | 1400*500*1150 | 1650*550*1250 | 1380*650*1400 | 1380*650*1400 |