Customization: | Available |
---|---|
After-sales Service: | Online Service |
Type: | Water-Cooled |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product Introduction:
1. Our Precision Oil Temperature Controller Unit stands at the forefront of technology by incorporating top-of-the-line imported compressor heads from Europe and America, delivering unmatched performance and reliability that you can count on.
2. Only the best for our customers: We use electrical components from globally acclaimed brands such as SIEMENS, Weidmuller, LG, MOELLER, and West, ensuring exceptional quality and enduring durability.
3. Our commitment to excellence is reflected in the use of advanced anaerobic welding techniques for steel pipes, which guarantees strong, leak-proof joints, ensuring utmost reliability.
4. Control Method: Experience unparalleled precision and flexibility with your choice of an imported microcomputer or a sophisticated PLC control system.
5. Stay ahead in automation with our unit's Rs485 communication capabilities, designed for effortless automated management (optional feature).
6. Discover peace of mind with our extensive safety features, clear fault displays, and a user-friendly maintenance system that requires no specialized skills.
7. Our high-efficiency evaporators and condensers are engineered to deliver remarkable energy savings of over 30%, making this unit an eco-friendly choice for the environmentally conscious.
8. Built with cutting-edge imported components, this product is meticulously designed to provide a long-lasting and dependable service life.
9. For models C-20 and above, experience enhanced operational flexibility with dual compressor heads that can be activated independently or together, as per your needs.
ITEM | UNIT |
ADDC-36 | ADDC-48 | ADDM-36 | ADDM-48 |
OT320D-24 | OT320D-30 | OT320D-24/2 | OT320D-30/2 | ||
Temp control range | ºC | Inlet water temperature +45ºC~320ºC | |||
Temp control accuracy | ºC | PID ±1 | |||
Power supply | AC 3N-380V/400V-50HZ(3 phase+Earth) | ||||
Heat transfer medium | Thermo conductive oil | ||||
Cooling method | Indirect Cooling | ||||
Cooling capacity | 0.36 | 0.48 | 0.36+0.36 | 0.48+0.48 | |
Expansion tank | L | 40 | 67 | 62 | 62 |
Heating capacity | KW | 15*2 | 20*2 | 30+30 | 40+40 |
Moter power | KW | 1.1 | 3 | 1.1+1.1 | 3.0+3.0 |
Pump flow | L/min | 30 | 75 | 30+30 | 75+75 |
Max. power consumption | KW | 31 | 43 | 62 | 86 |
Alarm function | //// Pump reversal/Oil shortage/Overheating/Overload/Abnormal heating |
||||
Cooling water pipe | inch | 1/2 | 1/2 | 3/4 | 3/4 |
Circulating oil pipe | inch | 3/4 | 1 | 3/4+3/4 | 1+1 |
Size(L×W×H) | mm | 1400*500*1150 | 1650*550*1250 | 1380*650*1400 | 1380*650*1400 |