Customization: | Available |
---|---|
After-sales Service: | Online Service |
Type: | Water-Cooled |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product Introduction:
1. Circulating pump
This cutting-edge circulating pump is equipped with an advanced magnetic drive system. It seamlessly ensures the continuous shaft's long-term operation, expertly preventing leaks and significantly enhancing the pump's overall durability.
2. High heat conduction efficiency
Experience extraordinary thermal transfer capabilities with a system that's approximately six times more efficient than conventional heat conduction oils, thus optimizing performance to new heights.
3. Heater
The heater is crafted with innovative design principles that resist dry burning and prevent scale build-up, ensuring both longevity and consistent, reliable heat output throughout its lifecycle.
4. IIOT
Harness the power of state-of-the-art monitoring systems to keep a keen eye on flow rate, pressure, and temperature. This ensures optimal performance and efficiency during every use, making operations smoother and more effective.
5. Safe and reliable
Engineered and manufactured to meet rigorous boiler standards, this system offers unparalleled safety and reliability, providing complete peace of mind with every operation.
6. Energy conservation and environmental protection
This system uses water as the heat conduction medium, presenting an eco-friendly and cost-effective solution that champions energy conservation and environmental protection.
ITEM | UNIT |
MODEL | |||
WT160D-18T/2 | WT160D-24T/2 | WT180D-24T/2 | WT200D-24T/2 | ||
Temp control range | ºC | +25ºC~160ºC Inlet water temperature |
+25ºC~180ºC Inlet water temperature |
+25ºC~200ºC Inlet water temperature |
|
Temp control accuracy | ºC | PID ±1 | |||
Power supply | AC 3N-380V/400V-50HZ(3 phase+Earth) | ||||
Heat transfer medium | Water | ||||
Cooling method | Indirect Cooling | ||||
Cooling power | KW | 200KW @160ºC | 200KW @160ºC | 350KW @180ºC | 400KW @200ºC |
Heating capacity | KW | 18*2 | 24*2 | 24*2 | 24*2 |
Motor power | KW | 1.7*2 | 2.5*2 | 2.5*2 | 2.5*2 |
Pump flow | L/min | 90 | 90 | 90 | 90 |
Pump head | m | 65 | 90 | 90 | 90 |
Max. power consumption | KW | 42 | 56 | 54.5 | 57.4 |
Alarm function | ////// Pump reversal/Water shortage/Overheating/Overloading/High pressure/pressure divergence/flow divergence |
||||
Circulating water pipe | inch | 3/4" *2 | 1" * 2 | ||
Cooling water pipe | inch | 3/4"+3/4" | 1"+1" | ||
Size(L×W×H) | mm | 1350*600*1300 |