Customization: | Available |
---|---|
After-sales Service: | Online Service |
Type: | Water-Cooled |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product Introduction:
1. Featuring state-of-the-art imported compressor heads from Europe and America, ensuring unparalleled performance and reliability.
2. Our electrical systems incorporate top-tier components from SIEMENS, Weidmuller, LG, MOELLER, ABB, and West, guaranteeing operational excellence.
3. Utilizing superior anaerobic welding methods for steel pipes, providing robust and leak-proof connections.
4. Advanced control options: Choose between imported microcomputer systems or sophisticated PLC controls to suit your needs.
5. Equipped with Rs485 communication capability, enabling seamless automated management and integration into modern workflows.
6. Comprehensive safety features, intuitive fault display, and user-friendly maintenance that require no specialized training.
7. High-efficiency evaporators and condensers designed to cut energy consumption by more than 30%, promoting cost-effective operations.
8. Built with premium imported components, ensuring a long service life and consistent performance.
9. Models C-20 and above are equipped with dual compressor heads, offering the flexibility to operate them individually or in tandem for optimized efficiency.
ITEM | UNIT |
ADDC-36 | ADDC-48 | ADDM-36 | ADDM-48 |
OT320D-24 | OT320D-30 | OT320D-24/2 | OT320D-30/2 | ||
Temp control range | ºC | Inlet water temperature +45ºC~320ºC | |||
Temp control accuracy | ºC | PID ±1 | |||
Power supply | AC 3N-380V/400V-50HZ(3 phase+Earth) | ||||
Heat transfer medium | Thermo conductive oil | ||||
Cooling method | Indirect Cooling | ||||
Cooling capacity | 0.36 | 0.48 | 0.36+0.36 | 0.48+0.48 | |
Expansion tank | L | 40 | 67 | 62 | 62 |
Heating capacity | KW | 15*2 | 20*2 | 30+30 | 40+40 |
Moter power | KW | 1.1 | 3 | 1.1+1.1 | 3.0+3.0 |
Pump flow | L/min | 30 | 75 | 30+30 | 75+75 |
Max. power consumption | KW | 31 | 43 | 62 | 86 |
Alarm function | //// Pump reversal/Oil shortage/Overheating/Overload/Abnormal heating |
||||
Cooling water pipe | inch | 1/2 | 1/2 | 3/4 | 3/4 |
Circulating oil pipe | inch | 3/4 | 1 | 3/4+3/4 | 1+1 |
Size(L×W×H) | mm | 1400*500*1150 | 1650*550*1250 | 1380*650*1400 | 1380*650*1400 |